20ml water sample cell with cap, clear, 25*60mm, flat bottom; 25mm FTU test vials, 6 pcs/pk
Details of Chemical Oxygen Demand Test:
2mL of a water or watse water sample are added to a 16mm glass culture tube containing the digestion reagent and a catalyst. The tube is capped with a polypropylene, PTFE lined cap and heated in a block digester at 150C for 2 hours. The orange Hexavalent chromium is reduced to a greenish trivalent chromium. The analytical range for the spectrophotometric method is 5-150ppm (measured at 420nm).
Aijiren uses high-quality raw materials to make 16mm Test Tube for Water Analysis. Customer satisfaction and praise have made Aijiren one of the largest laboratory consumables producers in southern China. First, Aijiren will stick original intention to ensure the quality of 16mm Test Tube for Water Analysis.
With the Aijiren COD tube test, each user can easily perform highly sensitive and accurate water detection. The time required for the measurement process is greatly shortened, especially for standard analysis and series measurement, while greatly reducing the workload.
It is worth noting that if the used COD Tubetests contain strong sulfuric acid and other chemicals, the reagents must be handled carefully. The items in the pipeline should be disposed of in accordance with the requirements of local authorities. These tubes can only be used once and cannot be reused.
Tube tests for photometric analysis convince by their easy handling and therefore are the first choice for routine, laboratory and process analysis. A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents.
Open COD test tube, hold it at an angle and slowly add 2.0 mL of the pretreated sample solution from the reaction tube without mixing so that two separate layers are formed. Screw cap securely on to test tube, hold tube by the cap, place tube into the safety bottle and shake (Caution, test tube becomes hot). Place tube into the heating block. Start heating programme. After 2 h remove test tube from heating block, allow to cool down to room temperature and shake gently several times. Clean outside of test tube and measure. Adjust photometer to zero by using blank value “NULL”
PP cap is made in one molded piece of inert, chemically resistant polyethylene. The starburst slits allows for easy needle penetration. Developed for high-sensitivity applications, especially in the LCMS Market, the purity of this cap for extractables is well below the picogram range. This highgrade polyethylene does not have the contamination issues PTFE/Silicone septa show at low levels of detection, while also sealing exceptionally well.
The COD tube provided by Aijiren uses high-quality glass, which is extremely inert and will not react with reagents. Through Aijiren COD tube test, the time required for the measurement process is greatly shortened, especially for standard analysis and series measurement, which greatly reduces the workload.
The COD Test Tubes produced by Aijiren are often used for digestion colorimetric experiments. This kind of experiment has high requirements for COD Test Tubes and has a wide range of applications. Pharmaceutical, petroleum, chemical, water quality, etc. all need to use digestion colorimetric experiments. experiment. Aijiren’s COD Test Tubes can well meet the requirements for consumables in the digestion colorimetric experiment.
To use the digital heater for the COD test, set the temperature on the digital display to 150°C. On no account must the heater be set at a higher temperature than that specified as this may cause a hazard through pressure build-up in the COD tubes.
Testing water for Total Organic Carbon (TOC) is no longer exclusive to the environmental industry. With the latest USP methods, TOC is now a concern for any industry using Purified Water and Water for Injection. Aijiren Low Level TOC Vials are specially cleaned and packaged to reduce TOC to the lowest levels possible, assuring a low background for your testing.
The COD Test Tube produced by Aijiren has a capacity of 10ml, 12ml, and 15ml. The caliber is 16mm. It is often used for water quality testing and contains liquid reagents. It is mostly used in the petroleum industry and chemical analysis.
Aijiren has been engaged in the production of COD test tube with Caps for more than ten years, we have absolutely rich experience and familiar processes to produce COD test tube with cap, and we can guarantee the high quality of COD test tube produced by Aijiren with reasonable price.
The Chemical Oxygen Demand (COD) test is widely used as a measure of organic contamination by determining the quantity of oxygen required for oxidation of reduced species including organic matter, in a water sample using a specific oxidizing agent, temperature and time reduction. COD testing is a good better indicator of organic pollutants in industrial wastewater containing cyanides and heavy metals. COD testing affords rapid response to changing conditions before critical problems develop.
Water Sample Cell Color: Clear Volume: 20ml, 30ml Size: 25x60mm, 25x95mm Cap: with black cap
With the Aijiren COD tube test, each user can easily perform highly sensitive and accurate water detection. The time required for the measurement process is significantly shortened, especially for standard analysis and series measurement, while significantly reducing the workload. The COD Test tube contains a precise dose of reagent. Therefore, excessive chemical inventory is avoided and work safety is improved.
Chemical oxygen demand is a vital test for assessing the quality of effluents and waste waters prior to discharge. The Chemical Oxygen Demand (COD) test predicts the oxygen requirement of the effluent and is used for monitoring and control of discharges, and for assessing treatment plant performance. The impact of an effluent or waste water discharge on the receiving water is predicted by its oxygen demand. This is because the removal of oxygen from the natural water reduces its ability to sustain aquatic life. The COD test is therefore performed as routine in laboratories of water utilities and industrial companies.
The used COD Tubetests contain strong sulfuric acid and other chemicals, so reagents must be handled carefully. The contents of the pipe should be disposed of in accordance with the requirements of local authorities. These test tubes are SGC certified. These tubes can only be used once, so they cannot be reused.
The Chemical Oxygen Demand (COD) test is widely used as a measure of organic contamination by determining the quantity of oxygen required for oxidation of reduced species including organic matter, in a water sample using a specific oxidizing agent, temperature and time reduction. COD testing is a good better indicator of organic pollutants in industrial wastewater containing cyanides and heavy metals. COD testing affords rapid response to changing conditions before critical problems develop. Lovibond’s COD vials are compatible with BOTH Lovibond and Hach® colorimeters.
The 16mm COD Test Tube produced by Aijiren is mostly used for laboratory chemical analysis. Aijiren believes that COD Test Tube requires high-quality raw materials and advanced technology to complete the production, so Aijiren is very attentive to the production of COD Test Tube. Aijiren has been a veteran in the field of chromatography consumables with 20 years of production experience. He still maintains his original intention and puts the improvement of product quality in the first place.
The COD Test Tubes produced by Aijiren are often used for chemical oxygen demand detection. The glass used in the COD Test Tubes produced by Aijiren has high temperature resistance, corrosion resistance, and can well protect the samples without affecting the experimental results. Aijiren’s raw materials are of high quality and production experience Abundant, with favorable product prices, it is a high-quality supplier of chromatographic consumables.
COD Test Tube is one of Aijiren’s main products. It can complete many important experiments, such as digestion colorimetry, water quality test, oxygen demand test, etc. The COD Test Tube produced by Aijiren has high inertness, good quality and stable tube. Aijiren has become a well-known manufacturer of chromatography consumables in southern China by virtue of the good quality of COD Test Tube.
TOC is the abbreviate by Total Organic Carbon. The TOC Direct Method from Aijiren provides a reliable and practical means for water treatment facilities to frequently measure organic carbon to optimize treatment processes. Instead of purchasing an expensive, traditional TOC analyzer or outsourcing TOC determinations to a contract laboratory, this method can provide TOC results — accurately and inexpensively — right at your facility, and without any hazardous waste.